Victron Battery Protect 12/24v – 65A

£44.40

Maximum continuous load current: 65A.

Peak current: 300A.

Operating voltage range: 6 –35 V.

Current consumption: 1.5mA when on / 0.6mA when off or low voltage shutdown.

Alarm output delay: 12 seconds.

Load disconnect delay / Load reconnect delay: 90 minutes (immediate if triggered by the VE.Bus BMS) / 30 seconds.

Default threshold – Disengage: 10,5V or 21V Engage: 12V or 24V.

Connection: M6.

Dimensions (HxWxD) / Weight: 59 x 42 x 115 mm / 0.2 kg.

Out of stock

SKU: 792-BPR000065400 Category: Tag:

Description

BatteryProtect 65A / 100A / 220A – With 7-segment LED display: easy to set up.

The BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.

12/24V auto ranging – The BatteryProtect automatically detects system voltage.

Programming made easy – The BatteryProtect can be set to engage / disengage at several different voltages. The seven segment display will indicate which setting has been chosen.

A special setting for Li-ion batteries – In this mode the Battery Protect can be controlled by the VE.Bus BMS.

Ultra low current consumption – This is important in case of Li-ion batteries, especially after low voltage shutdown.

Over voltage protection – To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16 V respectively 32 V.

Ignition proof – No relays but MOSFET switches, and therefore no sparks.

Delayed alarm output – The alarm output is activated if the battery voltage drops below the pre-set disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.

Delayed load disconnect and delayed reconnect – The load will be disconnected 90 seconds after the alarm has been activated. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the pre-set reconnect voltage.